U9210C 4 channel 10G full rate error meter

PRODUCTS > BERT Tester > U9210C 4 channel 10G full rate error meter

U9210C 4 channel 10G full rate error meter

Four channels parallel PG and ED; Single-ended clock output; PG and ED Supported rate range from 0.622 to 11.7 Gbps

BasicPerformance Features:

1、 Four channels parallel PGandED; Single-ended clock output.

2PGandEDSupport rate range from0.622arrive11.7 Gbps( Up to reach 15G, Requires optional).

3Support code type: PRBS7 / PRBS 9 / PRBS 15 / PRBS 23 / PRBS 31

4Supports continuous error detection and timed error monitoring.

5、 Communication mode: USB HID( Drive-free) orUSB-COM


Technical parameters

No.

parameter

Minimum

typical

maximum

unit

1

Data rate

0.622

0.6221.252.1252.4882.53.073.1254.255.06.1446.257.58.5 9.95310.0010.312510.5210.70911.0911.3211.7

11.7

Gbps

2

Number of channels


44Channel electrical port, supportPG and ED



3

Code type


PRBS7PRBS9PRBS15PRBS23PRBS31



4

Rise and fall time (20% to 80%


18

23

ps

5

Pattern reversal


Supports transmit and receive signal inversion



6

SignaldifferenceOutput amplitude

200

600

1000

mV

7

Data output jitter (RMS


1.510.3125GDown)


ps

8

Data input and output interface


difference,ACcoupling,50Ohmic impedance,SMA



9

Clock output

100

156.25

156.25

MHz

10

Data signal input sensitivity


50


mVpp

11

Data output eye diagram intersection point(difference)

49

50

52

%

12

USB HIDResponse time


10


ms

13

Operating temperature

10

25

50

°C

14

Operating voltage (AC)

180

220

250

V