U9264Q 400G PM4 Error tester

PRODUCTS > BERT Tester > U9264Q 400G PM4 Error tester

U9264Q 400G PM4 Error tester

Performance Features:

1、 Signal encoding mode:NRZandPAM4, Can be automatically NRZAtPAM4Free switching between signals.

2、 Eight-channel synchronous output for testing6.144G10G40G100G200Gand400GProducts, error code tests can be independently tested or eight-way synchronously.

3、 Supports continuous error detection and timed error monitoring.supportKP4/KR4 hardwareFECFunction

4、 NRZSupport rate:6.14410.31252525.7812526.562528.05 Gpbs.

5、 PAMSupport rate:14.062526.562528.9 GBd.

6、 NRZSupported code types:PRBS7910111523PRBS31User Defined.

7、 PAM4Support code type: PRBS11Q13Q15Q20Q23Q31Q49Q58QSSPRQJP03AJP03BUser Defined.

8、 The clock frequency is default4Dividing frequency, support1/4,1/8,1/16,1/32,1/64,1/128Frequency ratio.

9、 Communication method:USBchangeHID. No driver required, PCThe host computer software communicates with the device, sets the bit error instrument and tests the bit error rate.

 

Technical parameters

No.

parameter

Minimum

typical

maximum

unit

1

Signal encoding mode

NRZ/PAM4


2

Data rate

6.144

6.14410.3125202525.7812526.562528.05

28.05

Gbps

3

Code type

PRBS7PRBS9PRBS11PRBS13PRBS15PRBS16PRBS23PRBS31USER\ PRBS13QSSPRQJP03AJP03B


4

Rise and fall time (20% to 80%


14

35

pS

5

Pattern reversal

Automatic reversal of the signal at the receiving end


6

Signal output amplitude (single-ended)

200

800

1000

mV

7

25GData output jitter (RMS


500

700

fs

8

Data input and output interface

difference,ACcoupling,50Ohmic impedance, mother2.92mm SMA


9

Clock output

0.2

6.64

13.28

GHz

10

Data signal input sensitivity(Single-ended)


50


mVpp

11

Data output eye diagram intersection pointNRZ

49

50

52

%

12

PAM4Eye height (each eye height)

80

110

200

mV

13

PAMEye chart linearity

0.95

0.98

1


14

Operating temperature

10

25

50

°C