U9740B 56 Gbaud PAM4 CDR

U9740B 56 Gbaud PAM4 CDR

U9740B CDR( Clock recovery instrument) is mainly used to provide clock recovery signals in test environments without triggering clocks, thereby using sampling Oscilloscope test device optical eye diagram.Typical applications are testing of optical network devices, or forPONIn-applicableBOBProduct, due to the meteringThe backup itself has no frequency-dividing clock output, and the clock signal needs to be restored when testing the optical eye diagram to trigger the sampling oscilloscope.

    U9740B CDR( Clock recovery instrument) is mainly used to provide clock recovery signals in test environments without triggering clocks, thereby using sampling Oscilloscope test device optical eye diagram.Typical applications are testing of optical network devices, or forPONIn-applicableBOBProduct, due to the meteringThe backup itself has no frequency-dividing clock output, and the clock signal needs to be restored when testing the optical eye diagram to trigger the sampling oscilloscope.

    U9740B CDRWith oneFCOptical interface adapterApplicable toconventionalSFP28/56SRLRandBIDIWait for modulesThe optical signalAccesssupportNRZandPAM4Signal,FCOptical interface receptionThe optical signal is converted into an electrical signal.CDRThe clock of the electrical signal is then extracted and output, and the clock signal is mainly used for the trigger signal of the oscilloscope.

 

Technical Indicators

No.

Technique Technique refer to Standard

mostbigvalue

Min

unit

1

Data rate range

64

25

Gbps/Gbaud

2

Wavelength range (single mode)

1650

1250

nm

3

Optical input range

+5

-15

dBm

4

Clock recovery output frequency division ratio

2 / 4 / 8 / 16 / 32 / 64


5

Output electric clock amplitude

500( Typical value)

mVpp

6

CMLClock differential output amplitude

800

200

mVpp

7

Clock output random jitter

500

300

fs

8

Clock frequency (by28.1GbpsAs an example

14.05

0.44

GHz

9

Internal signal loss detection(LOS)

128 ( Overload)

5( Sensitivity)

mV

10

Power supply voltage(External power supply input voltage)

5.5

4

V

11

Operating temperature

70

10

12

Adapt module type (supportedNRZandPAM4Signal)

SFP28/56SRLRBIDI